Abstract: SA-PO1079
Continuous Oxygen Monitoring Reveals Link Between Arterial Oxygen Saturation Oscillations and Mortality Risk in Patients on Hemodialysis
Session Information
- Kidney Replacement Therapy and Care Delivery Innovations
October 24, 2026 | Location: Exhibit Hall A, Convention Center
Abstract Time: 10:00 AM - 12:00 PM
Category: Dialysis
- 801 Dialysis: Hemodialysis and Frequent Dialysis
Authors
- Nandorine Ban, Andrea, Renal Research Institute, New York, New York, United States
- Kotanko, Peter, Renal Research Institute, New York, New York, United States
- Kooman, Jeroen, Maastricht Universitair Medisch Centrum+, Maastricht, LI, Netherlands
- Usvyat, Len A., Renal Research Institute, New York, New York, United States
- Zhang, Hanjie, Renal Research Institute, New York, New York, United States
Background
Intermittent oscillations in arterial oxygen saturation (SaO2), described as saw-tooth patterns (STP), have been observed during hemodialysis (HD) (Zhang et al., BMC Nephrology 2025). Their clinical significance remains unclear. We evaluated the association between intradialytic SaO2 oscillation rate and mortality.
Methods
We analyzed a large US HD cohort from Jan 2021 to July 2023. SaO2 was continuously monitored during HD using the FDA-approved Crit-Line device, with measurements recorded every 10 seconds. For each patient, the percent of treatment time exhibiting oscillatory SaO2 patterns was calculated. Patients were stratified into two groups: <10% vs ≥10% oscillation time. Survival was assessed using Kaplan–Meier analysis and compared by log-rank test. A multivariable Cox proportional hazards model was fitted with adjustment for demographics (age, gender, race), comorbidities (COPD, CHF, diabetes), dialysis vintage, and clinical/laboratory parameters including albumin, hemoglobin, neutrophil-to-lymphocyte ratio, interdialytic weight gain, post-HD systolic BP, ultrafiltration rate, BMI, ESA dose, and average SaO2 at treatment start (5-20 minutes).
Results
After data cleaning, 31,337 patients were included. We recorded 4,625 deaths. Kaplan–Meier curves separated early with higher mortality in patients with ≥10% oscillation time (log-rank p<0.001) (Figure 1). In adjusted Cox analysis, greater SaO2 oscillation burden was independently associated with mortality (HR 1.03 per 10% increase; 95% CI 1.01–1.05; p=0.002).
Conclusion
Intradialytic SaO2 oscillations are independently associated with increased mortality in HD patients. Continuous SaO2 monitoring may identify high-risk individuals and represent a potential target for intervention.
Acknowledgment
Artificial intelligence tools were used to assist in the writing of this abstract. The authors reviewed and edited the content and take full responsibility for the final version.
Figure 1. Kaplan–Meier survival curves by saw-tooth pattern (STP) burden of intradialytic SaO2 (<10% vs ≥10%). Numbers at risk are shown.
Funding
- Commercial Support – Renal Research Institute, a wholly-owned subsidiary of Fresenius Medical Care.