Abstract: SA-PO0060
Automated Quality Control System for Artificial Intelligence (AI)-Based Measurements of Total Kidney Volume
Session Information
- Artificial Intelligence: Kidney Imaging, Pathology, and Precision Phenotyping
October 24, 2026 | Location: Exhibit Hall A, Convention Center
Abstract Time: 10:00 AM - 12:00 PM
Category: Artificial Intelligence, Digital Health, and Data Science
- 300 Artificial Intelligence, Digital Health, and Data Science
Authors
- Green, Abigail, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Dhar, Mrinal Kanti, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Gregory, Adriana, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Buchl, Samuel, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Holmes, Heather L., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Fati, Francesca, Mayo Clinic Minnesota, Rochester, United States
- Bozkurt, Elif G., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Khalifa, Muhammed, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Klug, Jason R., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Dachowicz, Adam P., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Cook, Cole J., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Conte, Gian Marco, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Shi, Tubo, Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Potretzke, Theodora A., Mayo Clinic Minnesota, Rochester, Minnesota, United States
- Kline, Timothy L., Mayo Clinic Minnesota, Rochester, Minnesota, United States
Background
Automated deep learning-based segmentation is increasingly used in medical imaging to enable rapid biomarker extraction. Time-consuming manual QC of segmentation outputs remains standard practice to ensure segmentation quality prior to downstream analysis. In autosomal dominant polycystic kidney disease (ADPKD), reliable segmentation is essential for accurate total kidney volume (TKV) measurement, which is a key biomarker for disease monitoring.
We developed and evaluated a 3D deep learning model that classifies input MR volumes and their automated segmentation outputs into three categories (Accept, Reject, and Rework) based on their predicted downstream success after manual review. Criteria contributing to these multiclass classification labels include image quality, image coverage of native kidneys, and segmentation accuracy.
Methods
We used a dataset of 16,492 abdominal magnetic resonance images (T2-weighted coronal scans) from patients with ADPKD for this study. Model training utilized 15,292 images, and performance was validated on a balanced set of 600 images (200 per class). A final balanced holdout test set of 600 images was used to evaluate model performance, with labels from two trained analysts and a radiologist as independent reference standards.
Results
The top-performing model (DenseNet121) achieved a median F1-score of 0.82 and median accuracy of 82% across reader-defined reference standards. Model-reader agreement measured by Cohen's κ ranged from 0.69-0.78, overlapping with the human interobserver range of 0.73-0.81. Most disagreement occurred at the subjective Accept-Rework boundary, consistent with demonstrated interobserver variability within both the validation and test datasets.
Conclusion
Downstream-aware multiclass classification models can provide scalable quality control of MR images and their automated segmentation outputs. This approach could be considered for: (i) clinical triage after automated segmentation to focus radiologist effort on flagged cases, and (ii) for automated data curation in research studies where time consuming review of images and automated segmentations is a significant bottleneck.
Acknowledgment
During preparation of this abstract, the authors used ChatGPT, OpenAI, GPT-5.4 Pro, for limited editorial suggestions related to wording and concision. No scientific content, data analysis, interpretation, images, or conclusions were generated by the tool. The authors reviewed and edited all text and take full responsibility for the integrity and accuracy of the submitted content.